150 GPM High Pressure Oil Filter PHA660MV1S1N7 Hydraulic Filter Housing

Short Description:

Operating medium: mineral oil, emulsion, water-glycol, phosphate ester

Operating pressure (max): 42 MPa (6000 psi)

Operating temperature: – 25℃~110℃

Indicating pressure drop: 0. 5MPa

By-pass valve unlocking pressure: 0.6MPa


Product Detail

Product Tags

Data Sheet

PHA oil filter housing
Model Number PHA 660 MV 1 S1 N7

PHA 660 MV 1 S1 N8

PHA Working Pressure: 42 Mpa
660 Flow rate:660 L/MIN
MV 25 micron stainless steel wire mesh filter element
1 With bypass valve
S1 Visual differential pressure clogging indicator
1 Seal material: NBR
N7/ N8 Connection thread:

N7:NPT 1 1/2

N8:NPT 2

description

High pressure  filter PHA

PHA high pressure hydraulic filters are installed in the hydraulic pressure system to filter solid particle and slimes in medium and effectively control cleanliness.
Differential pressure indicator and by-pass valve can be assembled according to actual requirement.
Filter element adopts many kinds of materials, such as glass fiber, stainless steel wire mesh and stainless steel sintered felt
Filter vessel is made of carbon steel, and has nice looking figure.

Odering Information

1) 4.CLEANING FILTER ELEMENT COLLAPSE PRESSURE UNDER RATING FLOW RATES
(UNIT:1×105Pa Medium parameters:30cst 0.86kg/dm3)

Type
PHA
Housing Filter element
FT FC FD FV CD CV RC RD MD MV
020… 0.16 0.83 0.68 0.52 0.41 0.51 0.39 0.53 0.49 0.63 0.48
030… 0.26 0.85 0.67 0.52 0.41 0.51 0.39 0.52 0.49 0.63 0.48
060… 0.79 0.88 0.68 0.54 0.41 0.51 0.39 0.53 0.49 0.63 0.48
110… 0.30 0.92 0.67 0.51 0.40 0.50 0.38 0.53 0.50 0.64 0.49
160… 0.72 0.90 0.69 0.52 0.41 0.51 0.39 0.52 0.48 0.62 0.47
240… 0.30 0.86 0.68 0.52 0.40 0.50 0.38 0.52 0.49 0.63 0.48
330… 0.60 0.86 0.68 0.53 0.41 0.51 0.39 0.53 0.49 0.63 0.48
420… 0.83 0.87 0.67 0.52 0.41 0.51 0.39 0.53 0.50 0.64 0.49
660… 1.56 0.92 0.69 0.54 0.40 0.52 0.40 0.53 0.50 0.64 0.49

2) DRAWINGS AND DIMENSIONS

DRAWINGS AND DIMENSIONS
Type A H H1 H2 L L1 L2 B G Weight(kg)
020… G1/2  NPT1/2  M22×1.5
G3/4  NPT3/4  M27×2
208 165 142 85 46 12.5 M8 100 4.4
030… 238 195 172 4.6
060… 338 295 272 5.2
110… G3/4  NPT3/4  M27×2
G1    NPT1    M33×2
269 226 193 107 65 --- M8 6.6
160… 360 317 284 8.2
240… G1    NPT1    M33×2
G1″ NPT1″ M42×2
G1″ NPT1″ M48×2
287 244 200 143 77 43 M10 11
330… 379 336 292 13.9
420… 499 456 412 18.4
660… 600 557 513 22.1

Size chart for inlet/outlet connection flange (for PHA110…~ PHA660)

p
Type A P Q C T Max. pressure
110…
160…

F1 3/4” 50.8 23.8 M10 14 42MPa
F2 1” 52.4 26.2 M10 14 21MPa
240…
330…
420…
660…

F3 1″ 66.7 31.8 M14 19 42MPa
F4 1″ 70 35.7 M12 19 21MPa